Check for uplift (pad and strip base:EC2)

Modified: 3 Oct 2019 Tekla Structural Designer 2025

Check for uplift (pad and strip base:EC2)

For combinations producing tension at the support the tension value is compared to the stabilizing loads. Auto-design can automatically increment the base size to achieve a passing status.

Was this helpful?
Submit