Scope (Eurocode EC1991-1-4 Wind wizard)

Tekla Structural Designer
Modified: 7 Feb 2025
2025
Tekla Structural Designer

Scope (Eurocode EC1991-1-4 Wind wizard)

There is no guidance in the standard for anything other than a cuboid building. In order to develop a tool for engineers, we have extended this capability to address non-rectilinear buildings. It is therefore the user's responsibility to ensure that the wind loading generated by the software meets the needs of any building with a shape that is beyond the scope of BS EN 1991-1-4:2005.

The scope of EN1991 1-4 Wind wizard encompasses:

  • Enveloping the building with wall panels and roof panels is undertaken in Tekla Structural Designer in the normal manner. There is only limited validation of the envelope defined (for example connected wall panels must have consistent normal directions). The onus is on you to model the building shape as completely and as accurately as you determine necessary.

  • Basic Wind Velocity and Peak Velocity Pressure is determined.

  • Having defined wall panels and roof panels (defaults are standard wall, flat or monopitch roof depending on the slope), you are able to specify the type in more detail e.g. multi-bay, monopitch / duopitch etc.).

  • The main wind parameters, are calculated for you but conservatively, (for example Crosswind Breadth, b, is determined for the enclosing rectangle of the whole building). Wherever possible other parameters are determined conservatively, but you are able to override the values should you need to.

  • Given the above, zoning is semi-automatic, (not attempted for roofs with more than 4 sides which are defaulted to single conservative coefficient), with full graphical feedback.

  • Load decomposition is fully automatic where valid, (wall panels and roof panels need to be fully supported in the direction of span).

Was this helpful?
Previous
Next