Steel seismic design to AISC 341
Additional seismic
provisions are required to be applied to members that are part of the seismic force
resisting system (SFRS) of a structure. These provisions are applied in addition to
any standard requirements for structural steel buildings as per AISC 360. The
seismic provisions are contained in AISC 341. Tekla Structural Designer covers non-seismic steel design to AISC 360-05, AISC 360-10 and AISC 360-016.
(Ref. 2). The purpose of this
guide is to describe the matching seismic design requirements contained in AISC
341-05, AISC 341-10 and AISC 341-16 (Ref. 5).
- Criteria assumed to be met (Seismic: AISC 341)
- Design philosophy (Seismic: AISC 341)
- Changes introduced in AISC 341-16 (Seismic AISC 341)
- Common seismic requirements (Seismic: AISC 341)
- Seismic checks - Beams (Seismic: AISC 341)
- Seismic checks - Columns (Seismic: AISC 341)
- Seismic checks - Braces (Seismic: AISC 341)