Combination generator (Australian Standards)
Note: The following are not considered
in Combination Generator:
- Construction Stage combinations - these must be created manually.
- Temperature and settlement loadcase types - these must be added manually.
Open the Combination Generator
Initial Parameters page
Combinations page
The following basic load combinations are created:
- 1.35 (Permanent)
- 1.2 (Permanent) + 1.5 (Imposed)
- 1.2 (Permanent) + 1.5 (ΨI * Long-term Imposed)
- 1.2 (Permanent) + 1.0 (Wind) + 1.0 (ΨC * Imposed)
- 0.9 (Permanent) + 1.0 (Wind)
Note: If minimum lateral loadcases have been specified in Model Settings extra combinations will be created for them in addition to the above.
Service page
This page indicates which combinations are to be checked for serviceability and the factors applied.
The following basic load combinations are created:
- 1.0 (Permanent)
- 1.0 (ΨS * Imposed)
- 1.0 (ΨI * Imposed)
- 1.0 (Wind)
Note: If minimum lateral loadcases have been specified in Model Settings extra combinations will be created for them in addition to the above.
- Should you require, you can also adjust the default factors applied in each generated combination.
- Click Next.
NHF (global imperfections) page
You can specify NHFs and factors in each of four directions. For each direction selected, a separate NHF combination will be generated.
Any combination with wind in is automatically greyed.
- Use the ‘Dir’ boxes to specify the directions in which the global imperfections are to be applied.
- Should you require, you can also adjust the default factors applied in each direction.
- Click Next.