Display mode shapes
-
Open a view and set the view
regime to Results View.
The Results ribbon is displayed.
- In the Result Type group, select the required analysis type, e.g. 1st Order modal.
- In the Loading list, select the required loadcase or combination.
- In the second list of the Result Type group, select the desired mode.
-
Still in the Result Type group, select between Mass Nomalized and Unity Nomalized
results.
Note: In the graphical view the only visible difference between Mass and Unity Normalized results is the tooltip information displayed as you hover over nodes (there is no change to mode shape).
- Select the diagram that you want to display.