Apply fire proofing
The Show/Alter State Fire proofing attribute allows you to graphically set and review the fire proofing applied to 1D member types.
Review fire proofing
- Open a view and change the view regime to Review View.
- On the Review tab, click Show/Alter State.
- Go to the Properties window.
- In the Attribute list, select Fire proofing.
-
Set the [M]ode to
Review
The member color coding indicates the fire proofing status. If working to Eurocodes the beams that have been set to have a fire resistance check are also indicated.
Note: By hovering the cursor over an individual member or panel a tooltip is displayed. This reports the cracked status, and also the EImajor, EIminor values. For partially cracked members/panels the percentage is also given.
Set as protected
- Open a view and change the view regime to Review View.
- On the Review tab, click Show/Alter State.
- Go to the Properties window.
- In the Attribute list, select Fire proofing.
- Set the [M]ode to Set On
- Set Checks to Protected
- Select which of the protection properties (exposure, shape, thickness & density) you want to apply proofing of the
- Select Entire member to apply the new setting to all spans/stacks, or leave it unselected to update individual spans/stacks only.
-
Click or box around those 1D
member(s) you want to set.
The member color coding updates to reflect the details that have been applied.
-
Members color coded as 'On' have the fire proofing that is shown in the properties window.
-
Members color coded as 'Other details' have other fire proofing properties. These are displayed in a tooltip when you hover the cursor over each member.
-
Set check for fire resistance (Eurocode only)
- Open a view and change the view regime to Review View.
- On the Review tab, click Show/Alter State.
- Go to the Properties window.
- In the Attribute list, select Fire proofing.
- Set the [M]ode to Set On
- Set Checks to Check for fire resistance
- Select Set exposure to specify whether the member is exposed on all sides or 3 sides only.
- Select Entire member to apply the new setting to all spans, or leave it unselected to update individual spans only.
-
Click or box around those beam(s) you want to set.
The member color coding updates to reflect the details that have been applied.
-
Members color coded as 'On' have the fire resistance that is shown in the properties window.
-
Members color coded as 'Other details' have other fire resistance properties. These are displayed in a tooltip when you hover the cursor over each member.
-
Toggle fire proofing settings
- Open a view and change the view regime to Review View.
- On the Review tab, click Show/Alter State.
- Go to the Properties window.
- In the Attribute list, select Fire proofing.
- Set the [M]ode to Toggle
- If working to Eurocodes, choose whether you want to toggle the protection or fire check settings.
-
Click or box around those 1D
member(s) you want to toggle.
The member properties toggle between on and off.