Loading settings
The Loading page and its subpages allow you to adjust certain loading settings
- in the current project - when accessed by clicking
- in new projects - when accessed by clicking
General
Item | Description |
---|---|
Use load patterning for steel beams |
When imposed/live loadcases have been set to be patterned, load patterning is automatically applied to continuous concrete beams. This option allows you to select whether similar patterning is applied to continuous steel beams. |
Use patterning of eccentricity moments for steel columns |
Allows you to select whether patterned eccentricity moments are considered in the design of steel columns. |
Pipework Operating & Testing Content Loadcase Type |
Allows you to select whether the ancillary loadcases created for lines of pipework are considered as Dead or Live (Imposed). |
Equipment Operating & Testing Content Loadcase Type |
Allows you to select whether the equipment loadcases created for operating and testing are considered as Dead or Live (Imposed). |
Line/Area Ancillary Loading
Item | Description |
---|---|
Ancillary Type |
Ancillary Type. |
Dead/Empty Load |
The default Dead/Empty Load factors applied for each type. |
Live (Imposed)/Content Load |
The default Live (Imposed)/Content Load factors applied for each type. |
Testing Content Load |
The default Testing Content Load factors applied for each type. |
Wind Loading
Item | Description |
---|---|
Entity Type |
The loadcase names that will be created when specific ancillary types have been specified. |
Shape factor Cf |
The default Cf factors come from the document ‘Wind Loads For Petrochemical And Other Industrial Facilities’ published by ASCE |
Effective Areaxy , xz |
The effective area of entity in xy and xz planes respectively. |
Factorxy , xz | Factor applied to the effective area of entity in xy and xz planes respectively. |
Area Per Lengthxz |
The area per length. |