Review and set live load reduction
By selecting the Live load reduction attribute in Show/Alter State you can graphically review and set live load reduction parameters.
Tip: Graphical editing will typically
be more effective than the alternative of opening the Properties dialog box for each member individually.
Review load reduction attributes
Tip: Hover the cursor
over a member to see all the above attributes in a tooltip.
Set 'Reduce live loads by' percentage for slabs
Tip: Hover the cursor over slabs that
don't have the currently selected percentage reduction to see their attributes
in a tooltip.
Set KLL factor
- Open a view and change the view regime to Review View.
- On the Review tab, click Show/Alter State.
- Go to the Properties window.
- In the Attribute list, select Live load reduction
- Set Mode to Set.
- Set the Load reduction attribute to KLL.
- Enter the KLL value.
- Uncheck Entire member if you only want the value to apply to individual stacks/spans.
- Click or box around entities to apply the new value.
Tip: Set the Entity type to
Beam, Column, or Wall to work on specific entities