Create pad bases
A reinforced pad base is an isolated foundation that supports a single column.
Create a pad base under a specific column
Create multiple pad bases
Override the loaded area to be used in the pad base punching check
When you create a pad base, initially the punching shear loaded area is based on the area of the column section being supported. If you require the punching check to consider an unmodeled base plate or pedestal you can do so by specifying a User loaded area as follows:
- Select the pad base.
- In Properties window, go to the Foundation Parameters section and select User loaded area.
- Specify a Loaded Area Breadth and Loaded Area Depth appropriate to the base plate or pedestal.