The checks are performed either by running Analyse All (Static) from the Analyse ribbon, or by running any of the Design (Gravity), or Design (Static) commands from the Design ribbon.
Note: For non-linear models with Tension Only bracing it is essential that the 'X Brace' pattern is used to input the braces as brace pairs rather than creating them individually. For linear analysis one of the braces in a brace pair is automatically inactivated, ensuring that the model's lateral stiffness, and hence lateral drift, is reasonably correct. If braces are input individually this will not be the case.
For those stacks to which the check has been applied, the storey drift in each direction (i.e. the difference between top and bottom deflection of the stack) is calculated, and from this the elastic critical load factor is determined.