XS_MAX_DECIMALS_IN_PROFILE_NAME

Tekla Structures
2022
Tekla Structures

XS_​MAX_​DECIMALS_​IN_​PROFILE_​NAME

Category in Advanced options dialog box

Profiles

Use this advanced option to control the number of decimals in profile names in NC file headers. The default value is 1.

Note:

This advanced option only affect plates created directly in the model. The advanced option XS_​PLATE_​ROUNDING_​DECIMALS affects plates created by components.

This advanced option works on plates only if you set the advanced option XS_​USE_​NEW_​PLATE_​DESIGNATION to TRUE on the Plate Work page in the Advanced Options dialog box.