XS_MARK_INTELLIGENT_POST_FREEPLACE_NEARBY
Category in Advanced options dialog box:Marking - general
If you set the advanced option
XS_MARK_INTELLIGENT_ POST_FREEPLACE_NEARBY
to
TRUE
(default),
Tekla Structures first places the marks in drawings avoiding crossing leader lines, and after that runs the place nearby command, which ensures that the mark locations follow the protection settings. If you set this advanced option to
FALSE
, the crossing mark check is performed, but the place nearby command is not run, so some of the protection settings may not be followed.
Note that you need to set the advanced option
XS_TRY_TO_KEEP_LOCATION_IN_FREEPLACING
to TRUE
(Default) for the advanced option
XS_MARK_INTELLIGENT_POST_FREEPLACE_NEARBY
to work.
This advanced option is model specific and the setting is saved in the options database.