Remove inconsistencies from a multi-user database

Tekla Structures
2021
Tekla Structures

Remove inconsistencies from a multi-user database

To preserve the integrity of your multi-user model, you need to remove any inconsistencies from the multi-user database at regular intervals, for example once a day. This may also fix assemblies with no main part and drawings of unknown (U) type.

We recommend you to check the multi-user database in single-user mode.

  1. Have all other users exit the multi-user model.

  2. Save your model to receive the modifications of other users.

  3. Exit the model.

  4. Open the model in single-user mode.

  5. Exit the model without saving.

  6. Re-open the model.

  7. On the File menu, click Diagnose & Repair and in the Model area, click Repair model.

  8. Save the model.

  9. Exit the model.

  10. Re-open the model in the multi-user mode.

Bylo to užitečné?
Předchozí
Další