Why are wall wind zones reported as Zero when I review the Zone Loads for wind load cases?
2022
Tekla Structural Designer
2023
Tekla Structural Designer
2024
Tekla Structural Designer
2025
Tekla Structural Designer
2026
Tekla Structural Designer
Environment
British Standard
Eurocode
Issue
Why are my wall wind zones reported as Zero?
Image
Resolution
In the screenshot below, the Load ribbon > Wind Load group > Wind Wizard... command has defined the Ground level as -0.5m. Wind is ignored below this value.
Image
If we review the Model ribbon > Levels group > Construction Levels command, the levels in the screenshot below are between -6m and 0m.
Image
The wind load is only applied beginning at the height of -0.5m as defined in the Wind Wizard.
Hence, the Zero locations are where the model falls below the Ground level of -0.5m where wind is ignored.
Image