I cannot launch the software and/or run commands when it is open after a period of use. I see "Error 18" and/or "Error 25" displayed within the License Manager. How can I resolve this?

Tekla Structural Designer
Tekla Tedds
Tekla Tedds for Word
2023
Tekla Structural Designer
2023
Tekla Tedds Tekla Tedds for Word
2022
Tekla Structural Designer
2022
Tekla Tedds Tekla Tedds for Word
2021
Tekla Tedds Tekla Tedds for Word
2021
Tekla Structural Designer
2020
Tekla Tedds Tekla Tedds for Word
2020
Tekla Structural Designer
2019
Tekla Tedds Tekla Tedds for Word
2019i
Tekla Structural Designer
2018
Tekla Tedds Tekla Tedds for Word
2019
Tekla Structural Designer
2018i
Tekla Structural Designer
2018
Tekla Structural Designer
Error 25
error
License Manager
Server
Environment
Not environment-specific

Issue

You have either of the following symptoms:

  • When trying to open Tekla Tedds the License Manager launches instead, stating Error 25 within the Status page with the following text:
    • Could not understand the message received from the License Manager on the specified host. The versions of the client and License Manager are incompatible
  • Or Tekla Tedds opens but after a period of use you cannot run commands (such as calculate) and get the following errors:
    • Error [18] No license code is available for feature "Tedds User (Legacy)" on host XXXXXX
    • When the License Manager is opened (from within the program) you see Error [25] Could not understand the message received from the License Manager on the specified host...

The issue also occurs for Tekla Structural Designer, Tekla Portal Frame Designer and Tekla Connection Designer.

Resolution

This is occurring because the Sentinel RMS version on the client (your computer) is newer than the version on the License Server.  So, the solution to this issue is to upgrade the Tekla Structural License Service on the License Server.

The version Tekla Structural License Service (4.4.x) is available in Tekla Downloads. It should be installed onto the License Server with the following options selected (note - select the third option only if your PC is also used on the license server).

 

Image
image.png

 

Due to significant changes to the current version of the Tekla Structural License Service, this upgrade is required on the license server to enable the use of the latest version of  Tekla Tedds (and any other current Analysis & Design product).

This installation is not required on the client machines.

 

Was this helpful?